MT-4E ANALOG & P25 DIGITAL RADIO SYSTEMS | MAINTENANCE GUIDE
Chapter 3: Test Equipment and Spares Page 9
CHAPTER 3: TEST EQUIPMENT AND SPARES
RECOMMENDED TEST EQUIPMENT
Codan Radio Communications recommends the following test equipment for maintenance of an MT-4E
radio system:
+13.8 Vdc Power Supply Codan PSA-12-40-RB-00
(rated for current draw of equipment) (40 Amp rack-mounted power supply)
ICT ICT24012 (60 Amp desktop power supply)
ICT ICT12012 (10 Amp desktop power supply)
Current Meter / Multimeter Fluke 75 Multimeter
Communications Service Monitor Marconi Instruments 2965A
(Analog) Aero ex IFR 1200 (Super S)
Aero ex IFR COM-120
Communications Service Monitor Aero ex IFR 2975
(P25 Digital and Analog) Aero ex IFR 3920
Aero ex IFR 3500
Aero ex IFR 3550
General Dynamics R2670
General Dynamics R8000
Alignment Tools Codan A-TK-04
RF Signal Sampler Bird Model 4275 Variable RF Signal Sampler
Wattmeter Bird Model 43 Wattmeter
It is recommended that when in the shop / service area, the Communications Service Monitor be
frequency locked to an external reference (WWVH, GPS, Loran C) so that the high stability local
oscillator may be accurately set to within its ±1 ppm frequency tolerance.
The test equipment should be calibrated on an annual basis to ensure accurate measurements.